HPLC/UHPLC

HPLC/UHPLC

    
 S3000 HPLC
 S3000 HPLC

S3000 HPLC

The S3000 high-performance liquid chromatography instrument adheres to Huapu's consistent development philosophy of high-performance liquid chromatography instruments. Based on further understanding u

Pump high precision, low pulsation, excellent stability

The pump system realizes the high precision mixing of the four-element gradient system, reduces the infusion pulsation, and ensures the accuracy of infusion and the stability of use.


 Special curve-shaped cam design

Special curve cam drive plunger makes the infusion more stable and lower pulsation.

 High-speed feedback, real-time control

Through the real-time pressure monitoring of the system, adjust the motor speed, with special, curve cam drive, and further reduce the flow stability.

■ Strcade inlet and outlet check valve design

Series two-stage pump head infusion is adopted, and the pump head inlet and outlet valves can ensure the infusion stability to a large extent and reduce the pulsation of the pump system.



Autosampler low residue, high precision, and excellent reproducibility

The automatic injection system adopts innovative injection system design and advanced direct injection method, with a new fit design, lower residue, stable reproduction, and fast injection to meet the high throughput requirements.


 Direct injection approach with low residues

Direct injection, as part of the flow path, ensures that all the samples enter the analysis system, avoids the waste of the samples, reduces the residue of the samples in the injection system, and ensures the reproducibility of high precision injection

 High-precision sample injection control

The new high-precision syringe drive unit is used to achieve excellent injection volume reproducibility and reliability of analysis results.


Column Oven

The column temperature box adopts the temperature control unit and specially designed preheating function to ensure the sharp, symmetrical and reproducible chromatography peak.


 Air circulation + preheating mode

The mobile phase is pre-heated before entering the column to reduce the interference to the temperature in the column.

The air inside the column temperature box is always circulating to ensure that the ambient temperature around the column is constant;

 Vertical column temperature box design

Vertical column temperature box can be placed into a larger column: compatible with 300mm long column, can be put up to 3 long chromatcolumns.

 The built-in switching valve can be configured

Reserved built-in switching valve installation valve position to meet the requirements of column switching or multi-dimensional chromatography application.


UV-detector

The UV detector, using high-quality optical unit and optimized optical path design, can provide higher sensitivity and meet the analysis of trace and trace samples.

 Quality optical unit

The body of the optical bench adopts the overall primary forming process to ensure the stable operation of the optical device under different temperature and humidity environments.

 Dual beam design

Using a dual beam design, the reference beam alone can effectively improve the baseline drift due to the aging of the optical components.


Specification:

Gradient mode:

Quaternary gradient

Flow rate range:

0.001-10.000 ml/min

Maximum pressure:

40MPa 

Max Injection volume:

100ul, can be extended to 1000ul

Sampler Temperature:

1-45℃ 

Sampler capacity:

120-bit 2ml vial, compatible with 96-well plates

Column temperature box temperature:

Room temperature +5℃-65

Automatic column switching valve:

Built-in type, optional

Column capacity:

Max 300mm long columns, up to 3 columns

UV detector

Dual beam design

wavelength self-calibration:

Built-in mercury lamp calibration

wavelength coverage:

190nm--700nm

Maximum sampling frequency:

100Hz

Message form

Thank you for your attention and trust in Acchrom Tech products. If you have any questions or abnormal situations with the products during browsing the website, please leave a message or call our company.
Customer Service Hotline :400-108-7908, We will contact you as soon as possible and wish you and your family happiness and health!